Product category: Waste management devices for disposable products
WASTE TREATMENT MACHINE ECODAS T100
Our patented process is designed to shred and sterilize infectious waste to reduce its volume, and render its components unrecognizable all in one fully enclosed and automated, stainless steel, system. It combines shredding, direct steam and high pressure to treat infectious materials.

The contaminated waste is loaded into the upper chamber where a heavy-duty, high-torque, low speed shredder reduces the waste into small pieces.

Using gravity, the processed material drop into the lower treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3,5 bar (51 psi) for 10 minutes. The operating and treatment conditions are continuously monitored and validated to achieve complete sterilization (Microbial inactivation = 10^8).

After the cooling process, the final product is volume-reduced (by up to 80 %), rendered unrecognizable and safe to recycle or to dispose as ordinary municipal waste.

The 30 minutes duration of an average cycle process is fully automated and totally monitored. A computerized control system scans the process and automatically prints a batch report at the end of each cycle with the essential sterilizing parameters for accurate record keeping.

Product category: Waste management devices for disposable products
WASTE TREATMENT MACHINE ECODAS T300
Our patented process is designed to shred and sterilize infectious waste to reduce its volume, and render its components unrecognizable all in one fully enclosed and automated, stainless steel, system. It combines shredding, direct steam and high pressure to treat infectious materials.

The contaminated waste is loaded into the upper chamber where a heavy-duty, high-torque, low speed shredder reduces the waste into small pieces.

Using gravity, the processed material drop into the lower treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3,5 bar (51 psi) for 10 minutes. The operating and treatment conditions are continuously monitored and validated to achieve complete sterilization (Microbial inactivation = 10^8).

After the cooling process, the final product is volume-reduced (by up to 80 %), rendered unrecognizable and safe to recycle or to dispose as ordinary municipal waste.

The 30 minutes duration of an average cycle process is fully automated and totally monitored. A computerized control system scans the process and automatically prints a batch report at the end of each cycle with the essential sterilizing parameters for accurate record keeping.

Product category: Waste management devices for disposable products
WASTE TREATMENT MACHINE ECODAS T2000
Our patented process is designed to shred and sterilize infectious waste to reduce its volume, and render its components unrecognizable all in one fully enclosed and automated, stainless steel, system. It combines shredding, direct steam and high pressure to treat infectious materials.

The contaminated waste is loaded into the upper chamber where a heavy-duty, high-torque, low speed shredder reduces the waste into small pieces.

Using gravity, the processed material drop into the lower treatment chamber, where every particle is steam heated to 138°C (280 F) and pressurized to 3,5 bar (51 psi) for 10 minutes. The operating and treatment conditions are continuously monitored and validated to achieve complete sterilization (Microbial inactivation = 10^8).

After the cooling process, the final product is volume-reduced (by up to 80 %), rendered unrecognizable and safe to recycle or to dispose as ordinary municipal waste.

The 45 minutes duration of an average cycle process is fully automated and totally monitored. A computerized control system scans the process and automatically prints a batch report at the end of each cycle with the essential sterilizing parameters for accurate record keeping.

ad: contact information

About Us

Company details
The ECODAS process is designed to serve the needs of infectious waste generators whether from the healthcare industry, food and animal meat processing, slaughterhouses, airports, airlines, seaports, or ships as well as the offsite service providers. The final treated waste is converted to safe neutralized waste that can be disposed off as regular municipal waste or it can enter a waste recovery chain. With a presence in over 100 countries, ECODAS company is the world leader in the treatment of infectious waste.

ad: company

Cousin Biotech S.A.S.
CREATEMPS SARL
CREATIVE EURECOM SAS
EDAP TMS S.A.
EDM GROUP MEDICAL IMAGING S.A.S
Electronica Technologies SAS Design, Manufacturing of audiometers
CREATIVE EURECOM SAS
CREATEMPS SARL
Cousin Biotech S.A.S.
COMEPA INDUSTRIES SAS
COMEG SA

EDAP TMS S.A.
EDM GROUP MEDICAL IMAGING S.A.S
Electronica Technologies SAS Design, Manufacturing of audiometers
ELITech Group SAS
Elkem Silicones France SAS